Real-time multi-gas measurement with Protea atmosFIR
Thermal runaway in lithium-ion batteries can produce a complex and rapidly changing mixture of gases and vapours. Protea’s atmosFIR FTIR gas analyser provides real-time multi-component analysis from a single instrument, allowing gases including CO2 CO2, HF, HCl and electrolyte carbonate vapours to be measured through the progression of a battery failure event. Protea has developed specific models for battery electrolyte carbonates including DMC, EMC, DEC, PC, EC and VC. [protea.ltd.uk]
The 1 cm-1 resolution of atmosFIR is a particular advantage when analysing complex gas mixtures, providing improved spectral information for separating and quantifying individual gas species. Protea identifies 1 cm-1 as its preferred high-resolution setting for gas analysis and uses a high-resolution calibration library at this resolution. Protea can provide a fully integrated FTIR measurement solution, combining the atmosFIR analyser, sampling system, PAS-Pro analytical software and application-specific gas calibrations into a complete system for battery thermal runaway research and testing.
Battery Off-Gas Analysis Before Thermal Runaway
Gas generation can begin before a battery enters full thermal runaway. Real-time FTIR analysis can therefore be used to investigate changes in gas composition as a battery progresses from abnormal operation and venting through to thermal runaway. atmosFIR provides continuous multi-gas measurement, allowing researchers to investigate the development of IR-active gases and electrolyte vapours during the different stages of battery failure.