Multi-gas analysis for electric vehicle battery fire and thermal runaway research
EV battery fire testing requires measurement of a complicated gas mixture that can change significantly as cells and battery packs progress through heating, venting, thermal runaway and fire. Protea atmosFIR provides continuous full-spectrum FTIR measurement, allowing multiple gases to be analysed simultaneously rather than requiring a separate analyser for each component. Protea's battery fire application includes measurement of electrolyte carbonates alongside gases including HF2 HCl and CO.
The atmosFIR platform combines 1 cm-1 high-resolution FTIR measurement with flexible measurement speeds and Protea's PAS-Pro analytical software. Protea states that changing atmosFIR speed and resolution does not require hardware changes, allowing measurement configuration to be selected for different applications. Protea can supply fixed or research systems incorporating a custom sampling system, allowing the FTIR, sample handling, measurement software and gas analysis to be supplied as a fully integrated solution for EV battery testing facilities and research laboratories.